Corrosion-Resistant Piping Solutions for Water, Wastewater & Industrial Applications

At HalfPipeSleeve, our Cement Lined Pipes and Spools range is engineered to protect steel, ductile iron, and cast iron piping systems from internal corrosion while delivering smooth, efficient flow characteristics. This category covers the complete piping package – Cement Lined Pipes, Cement Lined Fittings, Cement Lined Flanges, and prefabricated Cement Lined Spools – built to meet the demands of drinking water, cooling water, firewater, sewage, and process piping systems.

What is Cement Lining?

Cement lining is an internal coating applied to the bore of a pipe, fitting, flange, or spool using a mixture of cement, fine sand aggregate, and water (cement mortar), or a coarser cement-sand-gravel mix (concrete lining) for larger diameters. Once applied, the lining is cured, forming a dense, alkaline barrier between the metal wall and the fluid being conveyed.

This barrier works through two combined mechanisms:

  • Physical barrier protection – the cured cement layer physically separates the corrosive fluid from the base metal.
  • Alkaline passivation – hydrated cement carries a high pH (around 12.5), which promotes a passive oxide film on the metal surface and further resists corrosion.

The result is a piping product that resists rust, tuberculation, and scale build-up far longer than unlined steel or ductile iron, while also providing a smooth bore that improves hydraulic flow and reduces pumping energy losses.

Our Product Range

Cement Lined Pipes

Available in carbon steel, ductile iron, and cast iron, cement lined pipes are typically produced from NPS 2" up to NPS 84" (straight pipe lengths up to ~18 m). Lining is applied using high-capacity spray and centrifugal casting machines that uniformly distribute cement mortar against the inner pipe wall, producing a dense, smooth lining bonded to the steel.

Cement Lined Fittings

Elbows (90° & 45°), tees (straight & lateral), reducers (concentric & eccentric), crosses, end caps, bends (3D/5D), 180° returns, and saddles - manufactured to ASME B16.9 butt-weld fitting dimensions and lined per AWWA C205 standards. Due to the irregular bore geometry, fittings are typically hand-troweled or spray-lined, sometimes assisted by pneumatic placement tools, to ensure a compact and smooth internal finish.

Cement Lined Flanges

Flanges of any size and rating can be internally cement lined by hand-trowelling or spray application, maintaining lining continuity across flanged joints and ensuring the entire flow path - not just the straight pipe run - is corrosion protected.

Cement Lined Spools

Prefabricated pipe spools combine pipe, fittings, and flanges into shop-welded assemblies with cement lining applied and cured before dispatch. Spool fabrication reduces field welding, shortens installation time, and ensures consistent lining quality under controlled shop conditions rather than in the field.

Key Benefits

Typical Applications

Manufacturing & Lining Process

Lining Thickness Guide (Reference)

 

Nominal Pipe Size

Typical Mortar Lining Thickness

2″ – 10″

1/4″

12″ – 22″

5/16″

24″ and above

3/8″ – 1″ (concrete lining)

Actual lining thickness depends on project specification, fluid corrosivity, and the gover

Jointing Options

Cement lined systems can be joined using:

  • Buttweld joints – commonly used for larger sizes (>24″), with the cement lining stopped short of the weld area and made good with mortar patching after welding.
  • Sleeve joints – a jointing sleeve is shop-welded to one end, with the field weld completed on-site; a jointing compound seals the mating faces.
  • Flanged joints – widely used where disassembly or maintenance access is required.
  • Screwed/seal-ring joints – used on some smaller cement-lined pipe systems to keep corrosive media away from exposed steel at the joint.

Careful field jointing and inspection are essential – improperly repaired cement at joints or branch penetrations (e.g., weld-o-lets, thread-o-lets) can trap corrosive fluid between the lining and pipe wall, leading to premature failure. Bleed rings and reducing tees are commonly specified to minimize this risk.

Standards We Work To

  • AWWA C205 – Cement-Mortar Lining for Steel Water Pipe
  • AWWA C104/A21.4 – Cement-Mortar Lining for Ductile-Iron Pipe and Fittings
  • ASME B16.9 – Factory-Made Wrought Buttwelding Fittings
  • ASTM A234 / WPB – Fittings material grade
  • ASTM C541 – Linings for Asbestos-Cement Pipe (reference standard)
  • Client-specific and project-specific lining specifications

Why Choose HalfPipeSleeve

  • Complete category coverage: pipes, fittings, flanges & fabricated spools in one place
  • Lining applied and cured under controlled, quality-checked conditions
  • Compatible with carbon steel, ductile iron, and cast iron base materials
  • Manufactured to recognized international standards (AWWA / ASME / ASTM)
  • Suitable for both new pipeline construction and MRO/replacement projects
  • Technical support for lining selection, thickness, and jointing method

Need a cement lined pipe, fitting, flange, or spool built to your specification?

Contact our team with your size, pressure class, and service conditions, and we'll help you specify the right lining thickness, joint type, and material grade for your project.

Email sales@halfpipesleeve.com

Frequently Asked Questions

What is cement lining used for?
Cement lining is applied to the inner surface of steel, ductile iron, or cast iron pipes, fittings, flanges, and spools to protect the metal from internal corrosion. It’s most commonly used in drinking water, wastewater, firewater, cooling water, and oil & gas piping systems where the conveyed fluid would otherwise attack bare metal.
What is the difference between cement-mortar lining and concrete lining?
Cement-mortar lining is a mix of cement, fine sand, and water, generally used on pipe and fittings up to about 20″ in diameter. Concrete lining adds a coarse aggregate (gravel) to the mix and is used for larger sizes – typically 24″ and above – where extra thickness and strength are needed.
What sizes are available in cement lined pipes, fittings, and flanges?
Cement lined pipe is typically available from NPS 2″ up to NPS 84″, with straight lengths up to about 18 meters. Fittings and flanges can be lined in virtually any size to match the pipe run, since they are hand-trowelled or spray-lined rather than machine-cast.
How thick is the cement lining?
Lining thickness depends on pipe diameter, the applicable standard (such as AWWA C205 or AWWA C104/A21.4), and the corrosiveness of the service fluid. As a general guide, smaller pipes (2″–10″) use around 1/4″ of lining, mid-range sizes (12″–22″) use around 5/16″, and larger diameters (24″ and above) move into concrete lining at 3/8″ up to 1″ or more.
How does cement lining actually prevent corrosion?
It works two ways: the cured cement forms a physical barrier between the fluid and the metal wall, and the high alkalinity of hydrated cement (pH around 12.5) promotes a passive oxide film on the steel surface, which further resists corrosion.
Scroll to Top